Anytime. 
Along that thread, don't think that standard AOI machines for component inspection cannot do solder paste inspection. Many can do a decent job of detecting misprinted paste (misregistered), paste skips, slumped paste, and insufficient paste. Usually this needs to be a logarithm-based (grey-scale) machine, but even some comparison-based machines can do at least some type of paste inspection. So, if you have a 2D component inspection AOI machine, consider utilizing its capabilities to inspect paste prints. You will be surprised at what most of them can find, and even though it may not be perfectly optimal from a location standpoint, the number of defects they can find may be such that it is worth having an operator walk over and occasionally sample a print just to see if the print set-up/process is in control, especially if you can use a machine not required to run a different program, such as on another line not being used.
I have seen some shops put their benchtop manual unit on a rolling cart so it can be more easily used for both pre and post reflow inspection, and solder paste inspection as well. This makes for less walking/handling.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Amol Kane (Asteelflash,US)
Sent: Tuesday, January 24, 2012 2:29 PM
To: [log in to unmask]
Subject: Re: [TN] Solderpaste Inspection

I will believe it when I see the PO :-)....at least that's what I am
being told right now.

Anyway, I did look at cyberoptics and Koh Young already. I will have to
look at MVP and add them to our evaluation sheet...thanks Richard!


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Bavaro
Sent: Tuesday, January 24, 2012 3:20 PM
To: [log in to unmask]
Subject: Re: [TN] Solderpaste Inspection

$170K....Wow, I am jealous.  I am having trouble justifying to bean
counters here to buy a simple batch laser 3D system from ASC (only
$13k). In a former life, I believe we were using MVP so, as is usually
the case, Dean is right on the money and the first to reply.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Tuesday, January 24, 2012 12:03 PM
To: [log in to unmask]
Subject: Re: [TN] Solderpaste Inspection

MVP and Koh Young make excellent in-line SPI machines, and I am sure
there are others out there. I have direct experience with these two
machines here and at other client's sites, and we are all very happy
(and impressed) with their capabilities. Other machine you might want to
check is Cyberoptics.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Amol Kane
(Asteelflash,US)
Sent: Tuesday, January 24, 2012 1:39 PM
To: [log in to unmask]
Subject: [TN] Solderpaste Inspection

Dear Technetters,

We are looking to purchase in line solderpaste volume measurement
equipment (budgeted amount is 170K). The only fully automated in line
machines I have seen so far are from one US based manufacturer and a
Korean manufacturer. I am looking to see what are folks on technet using
and their experiences with the tool, both good and bad. Offline comments
would be highly appreciated.

 

Thanks,

Amol

 


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud
service.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives For
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud
service.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives For
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

------------------------------------------------------------------------
------
This message and any attachments are solely for the use of the addressee
and may contain L-3 proprietary information that may also be defined as
USG export controlled technical data. If you are not the intended
recipient, any disclosure, use or distribution of its content is
prohibited. Please notify the sender by reply e-mail and immediately
delete this message and any attachments.




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud
service.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2