I don't think they are acceptable. Many of the photos to demonstrate a
condition described as a process indicator per section 10.7.2 of IPC-A-610E.
bd7 12-15-11 looks like it might be a defect per 10.7.3, a breakdown of the
mask with metal inclusions. 
I agree with Brian, the whys are more troubling than the images. What is the
dark material running along the track under the mask on bd6? 
Guy

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of John Balchunas
Sent: Thursday, December 29, 2011 10:05 AM
To: [log in to unmask]
Subject: [TN] Soldermask, Receiving Inspection Photos

Greetings, and Thank you for your Counsel in the past.

 

What I bring before you today are some photos of Soldermask from some
PWBs in the as-received condition from the Supplier, and I would like to
hear what you have to say as to their Conformance to IPC Class 2
Requirements.  It will provide the feedback I need to assess my own
understanding of the criteria in IPC-A-600G and IPC-A-610E.

 

The photos are in my Soldermask, Receiving Inspection Photos Gallery at
the TechNet Group Site:

 

http://ipc-technet.groupsite.com/gallery/22209?page=1

 

Thanks again for your help with this.

 

John Balchunas

Supplier Quality Engineer

Email: [log in to unmask] <mailto:[log in to unmask]> 

Tel: 763-278-2249

Fax: 763-767-4635

 

 


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2