Pat, the reason I suggest kapton is due to it is on a signal line.   We were not told what kind signal line and performance requirements.  Kapton is a safer bet (still a bet) if low dielectric constant is required.  When I am in doubt, over kill usually saved day (just want to avoid nightmares). .  
--------------------------
Sent using BlackBerry


----- Original Message -----
From: Goodyear, Patrick [mailto:[log in to unmask]]
Sent: Wednesday, December 21, 2011 10:15 AM
To: [log in to unmask] <[log in to unmask]>
Subject: Re: [TN] QFP center slug over signal vias

 Ok I got into this discussion late as I have been off for a couple of days.   Is Glyptal red a good enough insulator?   It works for transformers and large motor windings.  Instead of trying the tape you could use a small applicator or stencil to dab a bit of Glyptal red onto the suspect problem area, should provide a high level of insulation.   I use it in ham radio work when I need high voltage isolation.  

Pat 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Bavaro
Sent: Tuesday, December 20, 2011 11:52 AM
To: [log in to unmask]
Subject: Re: [TN] QFP center slug over signal vias

I agree completely.  Sharing the pain always is a good learning experience.

-----Original Message-----
From: Joyce Koo [mailto:[log in to unmask]]
Sent: Tuesday, December 20, 2011 11:10 AM
To: Bavaro, Phillip @ MWG - TW; TechNet E-Mail Forum
Subject: RE: QFP center slug over signal vias

If you ask the designer to (1) tape the kapton tape on a piece of clean glass (cleaned using IPA and DI, followed by IPA rinse and dry)(2) cut into small pieces of the size using knife - under microscope if it is necessary, (3) put the piece on to the PWB at desired location using tweezers with proper ESD protection/with ionized gas blow on his hands.
I am sure you will never, ever see the same mistake again from the whole design group (the words get around very very quickly ;-).  My 1.92 cents. 

Joyce Koo
Materials Researcher - Materials Interconnect Lab Research In Motion Limited
Office: (519) 888-7465 79945
Mobile: (226) 220-4760


-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Tuesday, December 20, 2011 1:39 PM
To: Joyce Koo; TechNet E-Mail Forum
Subject: RE: QFP center slug over signal vias

Yeah, that was my first solution but unfortunately it is too small to
put Kapton on reliably (.006" x .015").   I tried to get it die cut but
could not get a quote.

-----Original Message-----
From: Joyce Koo [mailto:[log in to unmask]]
Sent: Tuesday, December 20, 2011 10:32 AM
To: 'TechNet E-Mail Forum'; Bavaro, Phillip @ MWG - TW
Subject: RE: QFP center slug over signal vias

Based on my book, solder mask is not consider as valid dielectric for signal.  (Kapton tape would be). 

Joyce Koo
Materials Researcher - Materials Interconnect Lab Research In Motion Limited
Office: (519) 888-7465 79945
Mobile: (226) 220-4760

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Bavaro
Sent: Tuesday, December 20, 2011 1:26 PM
To: [log in to unmask]
Subject: [TN] QFP center slug over signal vias

We found an existing design which has a device (QFP with center slug) that has too small of a center slug pad on the PWB.  Within the corresponding area where the center slug pad should have been, the designer put some signal vias.  Therefore the only thing preventing the signal via from shorting out to the center slug (ground) is the solder mask. No failures to date have been reported, even after a 20g vibe test.

Is this a violation of J-STD-001 or perhaps IPC-2221 -6.3.4 regarding minimum electrical spacing?  








______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.






---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

------------------------------------------------------------------------------
This message and any attachments are solely for the use of the addressee and may contain L-3 proprietary information that may also be defined as USG export controlled technical data. If you are not the intended recipient, any disclosure, use or distribution of its content is prohibited. Please notify the sender by reply e-mail and immediately delete this message and any attachments.




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2