Phil,

I would say this is a violation.  You may get away with this condition
if all parts are pasted and reflowed, but get bit if the part is touched
up by hand.  

Kapton tape is a good fix if it doesn't interfere with the stencil.  PWB
spin would be the best scenario.

Jim Carlson 
Quality/Configuration Manager 
L-3 Communications 
Applied Signal & Image Technology 
443-457-1111 Ext. 238


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Joyce Koo
Sent: Tuesday, December 20, 2011 1:32 PM
To: [log in to unmask]
Subject: Re: [TN] QFP center slug over signal vias

Based on my book, solder mask is not consider as valid dielectric for
signal.  (Kapton tape would be). 

Joyce Koo
Materials Researcher - Materials Interconnect Lab
Research In Motion Limited
Office: (519) 888-7465 79945
Mobile: (226) 220-4760

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Phil Bavaro
Sent: Tuesday, December 20, 2011 1:26 PM
To: [log in to unmask]
Subject: [TN] QFP center slug over signal vias

We found an existing design which has a device (QFP with center slug)
that has too small of a center slug pad on the PWB.  Within the
corresponding area where the center slug pad should have been, the
designer put some signal vias.  Therefore the only thing preventing the
signal via from shorting out to the center slug (ground) is the solder
mask. No failures to date have been reported, even after a 20g vibe
test.

Is this a violation of J-STD-001 or perhaps IPC-2221 -6.3.4 regarding
minimum electrical spacing?  



------------------------------------------------------------------------
------
This message and any attachments are solely for the use of the addressee
and may contain L-3 proprietary information that may also be defined as
USG export controlled technical data. If you are not the intended
recipient, any disclosure, use or distribution of its content is
prohibited. Please notify the sender by reply e-mail and immediately
delete this message and any attachments.




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud
service.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential
information, privileged material (including material protected by the
solicitor-client or other applicable privileges), or constitute
non-public information. Any use of this information by anyone other than
the intended recipient is prohibited. If you have received this
transmission in error, please immediately reply to the sender and delete
this information from your system. Use, dissemination, distribution, or
reproduction of this transmission by unintended recipients is not
authorized and may be unlawful.

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud
service.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------


CONFIDENTIALITY, EXPORT CONTROL AND DISCLAIMER NOTE: This e-mail and any attachments are solely for the use of the addressee and may contain information that is privileged or confidential. Any disclosure, use or distribution of the information contained herein is prohibited. In the event this e-mail contains technical data within the definition of the International Traffic in Arms Regulations or Export Administration Regulations, it is subject to the export control laws of the U.S. Government. The recipient should check this e-mail and any attachments for the presence of viruses as L-3 does not accept any liability associated with the transmission of this e-mail. If you have received this communication in error, please notify the sender by reply e-mail and immediately delete this message and any attachments.


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2