In addition, just by change the surface finishing (hole finishing) of the stencil, you would be able to increase/decrease amount of the paste. The opening should really linked to a specific finishing if you really really want to lock down the amount of paste. Being said that, I always like design in control of EVERYTHING (they should own everything). Put in to CAD may not be a bad idea if design know what they are doing in DETAILs ("devil" is in the details). My 1.92 cents.
Joyce Koo
Materials Researcher - Materials Interconnect Lab
Research In Motion Limited
Office: (519) 888-7465 79945
Mobile: (226) 220-4760
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Robert Kondner
Sent: Wednesday, December 14, 2011 9:54 AM
To: [log in to unmask]
Subject: Re: [TN] TI Paste Recommendations
Pete,
I would suggest that paste apertures should be part of a PCB CAD system though such is seldom, if ever, the case. Most CAD system do not support paste apertures well.
Yes, there are a lot of paste aperture modifications made to paste gerbers and that "Hand Tweaking" is a source for errors and inconsistencies.
As an example here is a link for something I worked up for parts reduction patterns, it is something I would like to see implemented in a paste aperture conversion code. I would also like to see the same kind of thing done for home plate aperture designs though that requires some knowledge of the components sitting at the aperture locations. This patter provides good support at thermal pad corners yet reduces allows for better outgassing than window pane patterns.
See: www.kondner.com/files/Stencil_5_Dot_Math.pdf
Dot Diameter = Sqrt(Rectangle) / 2
Bob K.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Pete
Sent: Wednesday, December 14, 2011 9:13 AM
To: [log in to unmask]
Subject: Re: [TN] TI Paste Recommendations
William, there's been some great information on QFNs posted in this thread, they are different than most SMT and it's good to know as much as you can about the assembly issues.
But from a CAD library standpoint, do you really need to define the paste footprint? Do you build home plate apertures into your 0603 footprints? There's a very good chance that manufacturing engineering is making quite a few modifications to your paste mask gerber file anyway. Check with them, they might prefer you just give them a gerber file that matches the pad shapes, and they will apply their expertise from there.
Now, via placement in and around the QFN, sodlermask apertures - those you need to be concerned with in your design. The Desginers Council Listserver had a discussion about some of this in the October archive.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|