Hi Dominic

I have a couple of questions before recommendations.

Is step on squeegee side or contact side in reference to your comment step-down vs step-up
Aperture size of the component closest to the 6/5 step and the 8/6 step

Regards,

Bill

 
William E. Coleman Ph.D.
Vice President Technology
Photo Stencil
4725 Centennial Blvd.
Colorado Springs, CO 80919
Office:     719-535-8528
Cell:         719-331-2433
Fax:         719-599-4334


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Dominic Boudreau
Sent: Thursday, November 10, 2011 10:57 AM
To: [log in to unmask]
Subject: [TN] Step Stencils design

Hello Technetters, I would like to request your help regarding step stencils; I never worked before with these of stencil so all recommendations would be really appreciated.  We have a step-up stencil that has 3 thicknesses: 8, 6 and 5 mils. Most of the stencil is at 6 mils and there are some areas that are at 8 and at 5 mils. The problem that we have is that the paste thickness that we obtain on the  5 and 6 mils areas is around  8 mils... The stencil has step-down from 8 to 6 mils and from 6 to 5 mils . Here are my questions:
 
1) Which keep-out out distance we should have. is the rule of thumb of IPC-7525  correct ( 35 mils for each 1 mil step thickness)?.
2) Which type of stencil is recommended , electroform?
3) Do we need a special type of squeegee blades?
4) Presently we use step-up stencil, should we use step-down stencil?
 
Thank you
 Dominic Boudreau  		 	   		  

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


CONFIDENTIALITY NOTICE: This e-mail transmission, and any documents, files or previous e-mail messages attached to it, may contain confidential information that is legally privileged. If you are not the intended recipient, or a person responsible for delivering it to the intended recipient, you are hereby notified that any disclosure, copying, distribution or use of any of the information contained in or attached to this message is STRICTLY PROHIBITED. If you have received this transmission in error, please immediately notify us by telephone at (719) 599-4305 and destroy the original transmission and its attachments without reading them or saving them to disk.  Thank you.

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2