Hi John,



We find that reliability testing is frequently required as part of the acceptance process. It would be prudent to simulate assembly and rework on a representative coupon. We typically test coupons "as received", after three thermal excursions to simulate assembly and six thermal excursions to simulate assembly and rework. We expect the greater the thermal excursion the less thermal cycles to failure. If there is a great reduction (poor interconnections) or and increase (material damage) in the cycles to failure we investigate further before the vender is qualified,



I think that a reliability test that includes assembly process must be part if the investigation for qualifying a bare board supplier. Then frequently a reliability test, not as thorough as the qualification test, is implemented for on going product procurement.



Best regards,



Paul Reid

PWB Interconnect Solutions

613 596 4244 ext. 229



  _____

From: TechNet on behalf of John Balchunas
Sent: Wed 09/11/2011 3:23 PM
To: [log in to unmask]
Subject: [TN] Qualification of PWB Suppliers...



All,



Does Final Assembly and Functional Testing add value to Qualifying Bare
Board PWB Suppliers?



Put another way...is a Supplier's Continuity/Isolation/Controlled Z
Testing, and their Customer's Inspection of the Physical Product to its
Documentation, sufficient to Qualify the Supplier without additional
Assembly or Functional Testing?



Thanks in advance for sharing your experiences with this.



John Balchunas

Supplier Quality Engineer

Email: [log in to unmask] <mailto:[log in to unmask]>

Tel: 763-278-2249

Fax: 763-767-4635






______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2