TECHNET Archives

November 2011

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Robert DeQuattro <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Robert DeQuattro <[log in to unmask]>
Date:
Mon, 7 Nov 2011 16:06:34 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (69 lines)
So I'm getting a lot of feedback in general that JBC's may not be the best selection for soldering irons. Would anyone like to comment on soldering irons in general, and their experience and perhaps even a preference or recommendation.

Thanks,

Bob

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tim Weller
Sent: Monday, November 07, 2011 7:19 AM
To: [log in to unmask]
Subject: Re: [TN] Soldering Iron Calibration Program

We are using the Weller WA-2000 Soldering Iron Analyzer.  It uses a
contact pyrometer that can be used with almost any soldering iron.  (I
have no relation to the company that I know of) We currently have Edsyn,
Metcal (Oki) and Hakko irons that we test.  We recently added the
de-soldering tools also.

 

Timothy T. Weller

Manufacturing Engineer

DICKEY-john Corporation

5200 Dickey John Road

Auburn, IL 62615

Tel 217-438-2455

Fax 217-438-2640

[log in to unmask]

 


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2