text/plain (116 lines)
When I thumb thru my specs I usually smear my lenses. Overlooking that transparent attempt at humor, a basic profile tolerance of 0.015" for a routed out assembly is the best you should ask for. With this in mind, if you needed to keep pads 0.025" from the edge, your design s/b 0.040" from the edge.

The Supplier's target on the max dimension with the 0.015" profile tolerance is going to then have a ± tolerance of 0.0075". Most Suppliers want ± 0.010".

Dewey 

 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kuczynski, Michael (H USA)
Sent: Wednesday, November 09, 2011 1:27 PM
To: [log in to unmask]
Subject: [TN] Tolerances for board and pads

 

While I go thumb thru my spec's, could anyone provide the following:

 

1) what is the REASONABLE tolerance for a PCB outline for a vendor to

hold? (board I'm working on is 10.85mm x 12mm, with a 4.5mm x 3.9 notch

taken out)

 

2) what REASONABLE tolerance can be held for copper pads to the board

edge?

 

thanks in advance

 

SIEMENS 

Michael Kuczynski     Healthcare Diagnostics Inc. 

Product Eng. II CID   511 Benedict Ave. 

914-524-3118 (Ph)     Tarrytown, NY 10591 

914-524-3322 (Fax)    Mail Stop P25-1-C 

[log in to unmask] 

 

-------------------------------------------------------------------------------

This message and any included attachments are from Siemens Healthcare Diagnostics

and are intended only for the addressee(s). 

The information contained herein may include trade secrets or privileged or 

otherwise confidential information. Unauthorized review, forwarding, printing, 

copying, distributing, or using such information is strictly prohibited and may 

be unlawful. If you received this message in error, or have reason to believe 

you are not authorized to receive it, please promptly delete this message and 

notify the sender by e-mail with a copy to [log in to unmask]

 

______________________________________________________________________

This email has been scanned by the MessageLabs Email Security System.

For more information please contact helpdesk at x2960 or [log in to unmask] 

______________________________________________________________________

 

---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 16.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2