TECHNET Archives

September 2011

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Julie Silk <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Julie Silk <[log in to unmask]>
Date:
Fri, 2 Sep 2011 12:47:46 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (12 lines)
We use a lot of QFNs, and manufacture some for our own use.  We have stopped using open vias -- no matter what the manufacturer says, the soldering is inconsistent and adding solder to compensate for wicking away can lead to the other issue of the ground pad lifting the part and causing opens.  Overprinting the groundpad (or pinpads) can also lead to connection between ground pad and pin pad solder and siphoning of the pin pad solder into the groundpad joint, causing opens.  We use the fill with epoxy and cap plate over method (which we call vippo, via in pad plated over).  This adds to the cost of the board because there are additional drilling and plating steps, but we get consistent results, better quality and the heat transfer is better.  We don't plate-shut , which I would guess is pretty specialized and expensive for thru vias.  Dave's followup sounded more like vippo.   We never use the cap one side method.  We have reliability concerns with trapping acids in this blind hole.  The issue with voids is another good one.  Definitely fewer voids with the vippo method, but it can still be a problem.  Optimization of the paste pattern and process help.  We have not tried the design to vent via diagonal solder mask presenting in a paper at IPC2011.    --Julie

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------