Yes, but they also want astronomical sums for them and minimum orders of 
250K syringes.  I have not checked with Portion-aire yet.

Doug Pauls



"Stadem, Richard D." <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
09/13/2011 11:19 AM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
"Stadem, Richard D." <[log in to unmask]>


To
<[log in to unmask]>
cc

Subject
Re: [TN] Pneumatic Syringes and ESD






Brian beat me to it, but yes, there are dissipative 5 ml and 10 ml and 
other size syringes available from Portion-aire and EFD and other 
companies.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Douglas Pauls
Sent: Tuesday, September 13, 2011 10:53 AM
To: [log in to unmask]
Subject: [TN] Pneumatic Syringes and ESD

Good morning all,

Time for a silly question.  The question has been raised internally as to 
the risk of ESD generation when an acrylic conformal coating (an 
insulative material) is applied using pneumatic syringes (also an 
insulative material), through a nylon brush (a third synthetic material).

1.  Do you know of any studies done benchmarking static generation levels? 

 We have done some here, but want to do a sanity check.
2.  If you have such devices in your facilities, what are your mitigation 
efforts?  Air ionizers, grounded tubes?
3.  Does anyone use, and can recommend, ESD safe syringe bodies and caps?

Many thanks in advance.

Doug Pauls
Rockwell Collins

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2