TECHNET Archives

August 2011

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Paul Reid <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Paul Reid <[log in to unmask]>
Date:
Mon, 8 Aug 2011 14:13:32 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (84 lines)
My guess is that this is best described as nodular plating. I don't
think it is burnt copper since it looks like there are nodules in the
PTH. Poor hole preparation and brighteners out of control would be in
the short list of candidates for root cause.

I doubt that this is a reliable PTH but objective evidence would be
preferred to my subjective opinion.

Sincerely,  
Paul Reid 
Program Coordinator  
PWB Interconnect Solutions Inc. 
235 Stafford Rd., West, Unit 103 
Nepean, Ontario Canada, K2H 9C1 
613 596 4244 ext. 229  
Skype paul_reid_pwb 
[log in to unmask] 
 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ed Popielarski
Sent: August 8, 2011 1:57 PM
To: [log in to unmask]
Subject: [TN] FW: [TN] Odd plating

Here's the pic

http://stevezeva.homestead.com/Odd_Plating.jpg

Thanks Steve!

Regards,

Ed Popielarski

Engineering Supervisor


NBS Corporation
2950 Patrick Henry Dr.
Santa Clara, Ca. 95054

Ph: 408-654-1100
Fx: 408-654-1107
Cl: 408-234-1497
Cl: 949-581-6601 (please use this number after hours)


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2