不同的引线、不同方向的偏出要求是不一样的。不能一概而论。
Best Regards,
James Liu 刘春光
Director, Industry Program 工业项目总监
IPC China
北京市经济技术开发区宏达北路18号大地国际大厦407A
Suite 407A Dadi International Building,#18 Hongda North Rd., BDA, 100176, Beijing China
Tel: +86 10 6788 5326
Fax: +86 10 6788 5326
MP: +86 136 0133 3491
[log in to unmask]<mailto:[log in to unmask]>
www.ipc.org.cn<http://www.ipc.org.cn/>
________________________________
发件人: Rainbow Zhang [[log in to unmask]]
发送时间: 2011年8月19日 14:04
收件人: James LIU Chunguang; TGAsia
主题: RE: Spring-pin off-center IPC-610
James, 你说的引线指的是Spring-pin的焊接根部?是有电镀Ni打底再镀金0.05~0.3U的. 我需要首先确认的是元件焊接部位跑出焊盘就一定是reject?如果可以accept那么接受条件又是怎么样的?IPC-610有相关定义?
Thanks
Rainbow
From: James LIU Chunguang [mailto:[log in to unmask]]
Sent: Friday, August 19, 2011 11:18 AM
To: TGAsia; Rainbow Zhang
Subject: 答复: Spring-pin off-center IPC-610
你的引线是什么形式的?
Best Regards,
James Liu 刘春光
Director, IPC China Training Centers/Technology 培训中心主任/技术总监
IPC China
北京市经济技术开发区荣华中路15号朝林大厦B05
Room B05, Zhaolin Building, #15 Ronghua Zhong Road, BDA 100176 Beijing China
Tel: +86 10 67885326
Fax: +86 10 67885326
MP: +86 136 0133 3491
[log in to unmask]<mailto:[log in to unmask]>
www.ipc.org.cn<http://www.ipc.org.cn/>
IPC中文培训官网:http://www.ipc.org.cn/Training-Certification/index.html
NEW:2011年10月成都/11月武汉/12月深圳
IPC2011年“热魔”杯手工焊接竞赛各分赛区期待您的参与!
IPC围脖,实时报道IPC中国动态,欢迎加好友!
搜狐:http://t.sohu.com/ipcchina
腾讯:http://t.qq.com/IPC_China
新浪:http://weibo.com/ipcchina
网易:http://t.163.com/ipcchina
[cid:[log in to unmask]]
发件人: TGAsia [mailto:[log in to unmask]] 代表 Rainbow Zhang
发送时间: 2011年8月19日 11:03
收件人: TGAsia
主题: Re: [TGAsia] Spring-pin off-center IPC-610
Hi 各位大虾,
我们厂现在有一FPC上面有2个焊盘位大小为3+/-0.05mm,需要SMT打2个Spring-pin (根部直径2.5mm)在上面 。 以前SMT是用翻转头会有20%左右的不良因为Spring-pin移位,跑出焊盘的区域,现在已经改用高精准的IC头了,但还是有1%左右的不良,SMT经理讲由于在回流焊过程中存在某些外界因素,比如,炉子里面有气流,焊料在融化时的拉力等,现在制程上已没有改良空间。恳请大家指教跑出焊盘位就要reject?我查阅了IPC-610的标准仅有关于PTH的相关标准,像我这种有定义接受标准?
[cid:[log in to unmask]]
Rainbow Zhang
Sr.Supplier Quality Engineer • FlexMedical(XiXiang) •[log in to unmask] • (+86755 8947 6888 #8050)
Legal Disclaimer: The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]<mailto:[log in to unmask]>
______________________________________________________________________
Legal Disclaimer: The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|