Hi Michael. It wasn't in the first release but IPC/WHMA-A-620A (July 2006) has the following in Clause 3.4:
These criteria apply to all cable or harness bundles, whether they are twisted pairs of the same wire type and size, or cables incorporating various wire types and sizes. The length of lay (or ''twist'') as measured from the midpoint of wire's crossover through a complete spiral to the next crossover midpoint of the same wire shall  be 8 to 16 times the outer diameter of the bundle (Figure 3-9). <Fig 3-9 is a drawing showing midpoint to midpoint measurement>

Acceptable - Class 1,2,3
* The length of lay for each twist is 8 to 16 times the outer diameter of the bundle.
Defect - Class 1,2,3
* The length of lay for each twist is less than 8 or more than 16 times the outer diameter of the bundle.

Jack

Jack Crawford, IOM
IPC Director Certification and Assembly Technology
IPC - Association Connecting Electronics Industries(r)
3000 Lakeside Drive, Suite 309 S
Bannockburn, IL, 60015
847-597-2893
FAX  847-615-5693
[log in to unmask]
www.ipc.org


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Forrester, Michael (H USA)
Sent: Wednesday, July 27, 2011 10:32 AM
To: Technet
Subject: [TN] Wire Twists per inch

Does IPC/WHMA-A-620 specify how many twists per inch you should have when you twist the wires in a cable assembly(like a twisted pair) instead of using tie wraps or lacing? 
I was unable to find anything.  Thank you.
 
Best Regards,
 
Michael Forrester
Sr. Product Engineer
CSMTPE
 
Siemens Healthcare Diagnostics
101 Silvermine Rd.
Brookfield, CT  06804
PH: (203) 740-6452
 

-------------------------------------------------------------------------------
This message and any included attachments are from Siemens Healthcare Diagnostics and are intended only for the addressee(s). 
The information contained herein may include trade secrets or privileged or otherwise confidential information. Unauthorized review, forwarding, printing, copying, distributing, or using such information is strictly prohibited and may be unlawful. If you received this message in error, or have reason to believe you are not authorized to receive it, please promptly delete this message and notify the sender by e-mail with a copy to [log in to unmask]

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2