Hello,

Any other opinions on the bubbles in the attached picture? Is it a
straight rejects?

Regards,
~wee mei~

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: Friday, July 15, 2011 9:26 PM
To: [log in to unmask]
Subject: [TN] FW: [TN] IPC-A-610 Conformal Coating - Coverage

Hi Wee Mei,

I have your picture posted here:

http://stevezeva.homestead.com/Wee_Coating.jpg

I would say that the trapped bubbles between the leads are a defect.
What
type of coating is it, acrylic or urethane?

Also I notice what looks like a very large horseshoe shaped bubble on
top of
the 8-leaded part in the upper right, aren't you worried about that?

Steve

-----Original Message-----
From: Lum Wee Mei [mailto:[log in to unmask]] 
Sent: Friday, July 15, 2011 1:26 AM
To: Steve Gregory
Subject: RE: [TN] IPC-A-610 Conformal Coating - Coverage

Steve,

Kindly upload my attachment for decision.

Thanks,
~wee mei~

-----Original Message-----
From: Steve Gregory [mailto:[log in to unmask]]
Sent: Thursday, July 14, 2011 10:42 PM
To: Lum Wee Mei
Subject: RE: [TN] IPC-A-610 Conformal Coating - Coverage

Hi Wee Mei,

If you want to send your image to me, I'll post it...

Steve

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lum Wee Mei
Sent: Thursday, July 14, 2011 10:29 AM
To: [log in to unmask]
Subject: Re: [TN] IPC-A-610 Conformal Coating - Coverage

Is that the image from NASA workmanship criteria acceptance for
conformal
coating? I am very curious to know why are bubbles not allow between the
leads? How did the 0.76mm diameter come about?

I will try to upload my image for further decision.

Thanks and Regards,
~ Wee Mei ~

  _____

From: TechNet on behalf of Steve Gregory
Sent: Thu 7/14/2011 9:02 PM
To: [log in to unmask]
Subject: Re: [TN] IPC-A-610 Conformal Coating - Coverage



Hi Jim,

Here ya' go:

http://stevezeva.homestead.com/Conformal_Coat.jpg

Steve

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Marsico, James - ES
Sent: Thursday, July 14, 2011 8:27 AM
To: [log in to unmask]
Subject: Re: [TN] IPC-A-610 Conformal Coating - Coverage

I know.  I sent a copy to Steve Gregory to post.

Jim Marsico
ITT Corporation
1500 New Horizons Blvd.
North Amityville, NY 11701
631-630-5079
[log in to unmask]


-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Thursday, July 14, 2011 8:26 AM
To: [log in to unmask]; Marsico, James - ES
Cc: [log in to unmask]
Subject: RE: IPC-A-610 Conformal Coating - Coverage

Jim,

   The provided URL address did not display an image.

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Marsico, James - ES
Sent: Thursday, July 14, 2011 6:27 AM
To: [log in to unmask]
Subject: Re: [TN] IPC-A-610 Conformal Coating - Coverage

In my humble opinion, your interpretation is correct, that is, no voids
are
allowed that bridge component leads.  The criteria below is what we use
in
our internal conformal coating document.  If you can't see the criteria
below please let me know and I can forward it to you directly.



[cid:[log in to unmask]]



Jim Marsico

ITT Corporation

1500 New Horizons Blvd.

North Amityville, NY 11701

631-630-5079

[log in to unmask]



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lum Wee Mei
Sent: Thursday, July 14, 2011 3:34 AM
To: [log in to unmask]
Subject: [TN] IPC-A-610 Conformal Coating - Coverage



Dear All,





Can some kind souls help me to interpret the below statement taken out

from IPC-A-610 Section 10.5.2.2 Conformal Coating - Coverage? I am look

at Class 3 and I am loss on its interpretation, especially 'Voids or

bubbles'.





Acceptable - Class 1, 2, 3



No bridging of adjacent lands or conductive surfaces from :



*         Loss of adhesion (mealing)



*         Voids or bubbles



*         Dewetting



*         Cracks



*         Ripples



*         Fisheyes or orange peel





It is common to find bubbles trapped between the soldered leads of those

gull-leaded components and between closely mounted SMDs passives for

brushing method. Are these bubbles allow for Class 3?





Thanks and regards,



~wee mei~





______________________________________________________________________

This email has been scanned by the MessageLabs Email Security System.

For more information please contact helpdesk at x2960 or
[log in to unmask]

______________________________________________________________________



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 16.0

To unsubscribe, send a message to [log in to unmask] with following text
in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest

Search the archives of previous posts at:
http://listserv.ipc.org/archives

For additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815

-----------------------------------------------------

________________________________
This e-mail and any files transmitted with it may be proprietary and are
intended solely for the use of the individual or entity to whom they are
addressed. If you have received this e-mail in error please notify the
sender.
Please note that any views or opinions presented in this e-mail are
solely
those of the author and do not necessarily represent those of ITT
Corporation. The recipient should check this e-mail and any attachments
for
the presence of viruses. ITT accepts no liability for any damage caused
by
any virus transmitted by this e-mail.

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per
day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per
day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per
day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per
day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2