Ken,
Try Taconic's RF301 and RF30 or Arlon's AD300A or CLTE-XT
But believe you my have an issue with Arlon's product out-gassing
Roger Tingler
Methods Engineer
Colonial Circuits
V:800-578-9602 x102
540-752-5511x102
F:540-301-2050
540-752-2109
E-mail: [log in to unmask]
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kenneth J. Wood
Sent: Friday, July 29, 2011 9:52 AM
To: [log in to unmask]
Subject: [TN] High Vacuum Substrate
Hi all,
I have a PCB that operates inside a vacuum chamber under ultra high vacuum.
The material can't outgas and needs to hold up physically under the pressure (or lack thereof).
I wanted to use RO3003 but may need something else, any suggestions?
Material lead time is an issue as well which is why I'm looking...
Thanks
Ken
_____________________________________
Kenneth J. Wood
Saturn PCB Design, Inc.
www.saturnpcb.com
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|