Uppina,
Have you verified vacuum levels and rf generator output?
Vacuum leaks will result in a pink color instead of blue in you chamber.
Depending on the type and power of the rf generator you may have power
loss or maybe an issue with the matching network. You can see these in
low of fluctuating power meter levels.
If you see lightening flashes in your chamber you may have a broken
insulator.
When was the last time the flow meters were calibrated, maybe your not
getting the gas flow you think you have.
good luck,
Chuck
Charles W. Brummer | 3M Manufacturing Engineer
3M Electronic Solutions Division
3M Canoga Park, 8357 Canoga Ave. | Canoga Park, CA 91304
Office: 818 734 4930
[log in to unmask] | www.3M.com
This message (including any attachments) may contain material, non-public
information or proprietary information and is for the intended recipients
only. If you are not the intended recipient, you should notify the sender
and delete this message. Any disclosure, copying, or use of this
information is strictly prohibited and may subject you to legal liability.
From:
Uppina Nagaraj <[log in to unmask]>
To:
<[log in to unmask]>
Date:
07/28/2011 10:01 AM
Subject:
[TN] Query on Plasma Desmearing
Sent by:
TechNet <[log in to unmask]>
Hi All,
We are manufacturers of bare PCBs and as a part
of PCB processing we have Plasma desmearing step.
Recently we're having some problem in getting etchback
in PTH consistently. We have a plasma desmearing machine,
where the loading of the panels is done horizontally.
The plasma desmearing is done in 2 cycle steps...
a) First cycle is done by purging O2
b) Second cycle is done by purging O2 & CF4
The volume of the gas and the duration of desmearing
is set based on the material type and the thickness of the PCB.
Our processing parameters are set since quite some time and we
didn't had any issues in getting etchback consistently. We've not
changed any process parameters and/or the supplier source.
We are checking the level of desmearing by conducting desmearing on
bare epoxy sheets and checking the weight loss. The results of
the weight loss are also not consistent. The results are similar
in the PCBs also, the etchback is not consistent.
It would of great help if anyone can share the possible causes
of the problem and suggest remedies for the same.
Thanks in advance!
Best Regards,
U.Nagaraj
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|