Hi All,
We are having some issues with lo-flow pre-preg . 1) we are trying to determine from the IPC spec what is the thickness tolerance allowed b) we are seeing a lot of what best can be described as "tiger stripes" throughout the pre-preg. Finally is there an outside lab that can test for resin/glass content that anyone knows.
Regards Steve
---------------------------------------------------