Stewart,
Definitely check in with the folks at Brush Wellman - Now called Materion, I
believe. http://materion.com/Businesses/Brush%20Performance%20Alloys.aspx
Other than that, be sure to keep the saw and polishing apparatus wet at all
times if you are one that may be sensitive to it.
http://www.berylliumsafety.com/
http://materion.com/en/Resource%20Center/Environmental%20Health%20and%20Safe
ty/Material%20Safety%20Data%20Sheets/~/media/Files/Old%20PDFs/Ceramics/C10%2
0Beryllia%20Ceramic.pdf
and the hazardous waste complications....
Best wishes for safe cutting and polishing.
Steve Creswick
http://www.linkedin.com/in/stevencreswick
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stewart McCracken
Sent: Monday, May 09, 2011 5:32 PM
To: [log in to unmask]
Subject: [TN] Micro-Sectioning Beryllia (BeO)
Fellow Technetters,.
I'm looking for advice / partner lab. in connection with setting up a line
in our lab to handle micro-section preparation of beryllia (BeO). Does
anyone have experience of handling requirements and or line set-up? After
some initial research our lab manager it looks like we need to house a saw
and grind / polish station in a filtered fume hood (glove box even?). Key
requirement being the capture and safe disposal of any aerosol /
particulates generated through the micro-section preparation process.
Would really appreciate any feedback or contacts and chance to discuss.
Thanks and kind regards,
Stewart
Stewart McCracken
MCS Ltd.
Centre House
Midlothian Innovation Centre
Roslin
Midlothian
EH25 9RE
U.K.
t. +44 (0)131 440 9090
m. +44(0)7711 541735
e. [log in to unmask]
w. www.themcsgroup.co.uk
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|