Gilbert

I am giving a paper at Apex that goes after this problem.


Best regards
Lee
J. L. Parker, Ph D
JLP Consultants, LLC
804 779 3389



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Gilbert Min
Sent: Tuesday, April 05, 2011 8:52 PM
To: [log in to unmask]
Subject: [TN] Peel strength Value

Dear Netters.

I got a defect from customer for peel off problem. Defect was observed
between Cu foil and epoxy material.
I can not find true root cause yet.
And I tried to do the peel strength Test with defective boards.
Test codition: Cu plating thickness 32um. Length 2.3cm. Trace width : 253um
Peel strength Value: 0.11 kg.f Normal boards: 0.11 / 0.10 / 0.11/0.10 Defect
boards:  0.10 / 0.10 / 0.11 I'm not sure that is these value acceptable?

I know different test condition for peel strength. But I would like to know
any possiblity to do Peel strength test with actual sample not test
specimen..
And How can I convert these test value to normal test condition or value?

Would you share your wisdom to me?
Thanks

--
Best Regards
*GIlbert*


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2