An informal intro to some practical design points:
Fast-forward to around the 18-minute mark...
http://www.youtube.com/watch?v=VXE_dh38HjU
-Chris
On 4/28/2011 6:10 PM, Larry Dzaugis wrote:
> 1. What size panel does your PCB fabricator run? There is software that will
> optimize your yield.
> 2. How is the assembly de-paneled? There may be an .092" or more between
> PCBs. V-score has less waste but clearance from the score is required.
> 3. An 18x5 may print but a 20 x4.5 may not. Can your handling equipment,
> magazines, conveyors work with a 18" long PCA? Placement machines may have a
> problem reaching all the locations, additional feeders may be required to
> have the head reach all the points. Some machines have a large placement
> rate drops due to the panel configuration.
> 4. Test OK with this size?
>
>
> As usual what makes sense is dependent on your suppliers, current equipment
> set and volumes.
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 16.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|