TECHNET Archives

April 2011

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Brad Saunders <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Brad Saunders <[log in to unmask]>
Date:
Sat, 2 Apr 2011 09:06:41 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (151 lines)
James, I certainly agree with your statement and would add ink is most predominate.  I have run into more issues on correct symbol such as where is equipment assembled or sold as there are several different UL symbols and definitely an important point of using UL certified constructions as weeks go by for UL approval for new build. It depends on how busy they are.
Boston Brad 
  ----- Original Message ----- 
  From: James<mailto:[log in to unmask]> 
  To: [log in to unmask]<mailto:[log in to unmask]> 
  Sent: Tuesday, March 29, 2011 4:56 PM
  Subject: Re: [TN] UL and Bare Board Fabrication


  Either Method may be requested buy the end user. Either method is
  acceptable 


  James Hofer
  General Manager
  Accurate Circuit Engineering (ACE)
  3019 S. Kilson Dr.
  Santa Ana CA 92707-4202
  [log in to unmask]<mailto:[log in to unmask]>
  (714) 546-2162 wk
  (714) 473-6127 cell

  -----Original Message-----
  From: [log in to unmask]<mailto:[log in to unmask]> [mailto:[log in to unmask]] 
  Sent: Tuesday, March 29, 2011 1:23 PM
  To: [log in to unmask]<mailto:[log in to unmask]>; James
  Cc: [log in to unmask]<mailto:[log in to unmask]>
  Subject: RE: [TN] UL and Bare Board Fabrication

  Does UL require that a PWB vendor inscribe their logo on the bare copper
  image.   This is what I grew up with and am confused now as I see PWB
  vendor inscribe their logo with white silk screen.

  "x"

  -----Original Message-----
  From: TechNet [mailto:[log in to unmask]] On Behalf Of James
  Sent: Tuesday, March 29, 2011 3:10 PM
  To: [log in to unmask]<mailto:[log in to unmask]>
  Subject: Re: [TN] UL and Bare Board Fabrication

  Manufacturing a bare PCB (as we do) with our UL approved and audited
  processes allows us to put "our" UL logo on the PCB making it a UL
  compliant PCB. We are restricted as to what specific processes or types
  of PCB's we are UL approved for and each type or process requires us to
  apply for UL approval if we want to certify it.


  James Hofer
  General Manager
  Accurate Circuit Engineering (ACE)
  3019 S. Kilson Dr.
  Santa Ana CA 92707-4202
  [log in to unmask]<mailto:[log in to unmask]>
  (714) 546-2162 wk
  (714) 473-6127 cell

  -----Original Message-----
  From: TechNet [mailto:[log in to unmask]] On Behalf Of Jack Olson
  Sent: Thursday, March 24, 2011 7:52 AM
  To: [log in to unmask]<mailto:[log in to unmask]>
  Subject: [TN] UL and Bare Board Fabrication

  Greetings,

  We are reviewing our bare board procurement document and Fab Notes, and
  I'm stuck on the part about UL. Reviewing notes from other sources I
  don't see any mention of UL, but I know fabricators have some kind of UL
  approval process (and the 94-Vx rating) and a UL registered logo? (I
  don't know).

  My question is, is the UL involvement primarily for the flammability of
  the MATERIALS they use, or is there more to the story?

  More to the point, Is there any reason to specify UL on a fabrication
  drawing (or in a general requirement?)

  thanks,
  Jack


  ______________________________________________________________________
  This email has been scanned by the MessageLabs Email Security System.
  For more information please contact helpdesk at x2960 or
  [log in to unmask]<mailto:[log in to unmask]>
  ______________________________________________________________________

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
  unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
  (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET
  Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
  posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest Search the
  archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives> Please
  visit IPC web site
  http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums<http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums> for additional
  information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100
  ext.2815
  -----------------------------------------------------

  ______________________________________________________________________
  This email has been scanned by the MessageLabs Email Security System.
  For more information please contact helpdesk at x2960 or
  [log in to unmask]<mailto:[log in to unmask]>
  ______________________________________________________________________

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
  unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
  (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET
  Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
  posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest Search the
  archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives> Please
  visit IPC web site
  http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums<http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums> for additional
  information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100
  ext.2815
  -----------------------------------------------------

  ______________________________________________________________________
  This email has been scanned by the MessageLabs Email Security System.
  For more information please contact helpdesk at x2960 or [log in to unmask]<mailto:[log in to unmask]> 
  ______________________________________________________________________

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 15.0
  To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums<http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums> for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815
  -----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2