Hi Pete,

Could look into copper pattern causing differential press pressures
resulting in resin starved/glass rich areas in one area and areas of
higher resin content in others. As Dk depends upon this mix, could be
affecting at RF. Look through the stack and identify consistently high
copper density areas. Also, find out how many fabricator put into
daylight of press - if too many or with "soft" dielectrics, the pressure
transfer varies from outer to middle as does the heat transfer.

Best Regards,
Phil.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Pete
Sent: 22 March 2011 15:18
To: [log in to unmask]
Subject: [TN] Fabrication failures in one area of board?


               *** WARNING ***

This mail has originated outside your organization, either from an
external partner or the Global Internet. 
     Keep this in mind if you answer this message. 

We are trying to get an RF board functioning, and are having
difficulties in the same area of a couple boards.  The circuit turns on,
but with drastic performance differences

This board has 4 identical TX Channels, Channel 1, at the edge of the
board works every time, but as we move inward, we experience more
failures.  
Channel 4, at the center of the board will not perform properly on any
board.

A visual examination doesn't show any differences that might impact
performance.  The soldering process looks OK.

Is there something that could likely vary in the fabrication process
that might cause this?  It's (supposed to be) a standard 170Tg,
non-dicy, RoHS fab.  
High copper density, but the center channels are near an area of less
copper density.  Could an epoxy curing variation occur, that might
impact getting a consistent dielectric result?  What should I be looking
for?  These boards were not ordered from our qualified vendor, and I
have some concerns.  We had issues with them before.

Pete

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

********************************************************************
This email and any attachments are confidential to the intended recipient and may also be privileged. If you are not the intended recipient please delete it from your system and notify the sender. You should not copy it or use it for any purpose nor disclose or distribute its contents to any other person. 

MBDA UK Limited, a company registered in England and Wales, registration number 3144919 whose registered office is at Six Hills Way, Stevenage, Hertfordshire, SG1 2DA, England.
********************************************************************

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2