Hi Richard - very good discussion! I have the luxury of having a SERA 
tester to measure the oxidation state of my immersion silver pwbs so I can 
determine just have bad things are getting. Here is some wording we use on 
our product floor to assist with the "changing visual appearance" of 
immersion silver finishes. This rule of thumb isn't perfect but has been 
helpful.

Immersion Silver Visual Appearance Rule of Thumb:
Immersion silver surface finishes will discolor as a printed wiring board 
goes thru the assembly process. This discoloration is oxidation and not 
corrosion with one exception. The typical discoloration has a yellow to 
goldish tan to light brown visual appearance which is cosmetic in nature. 
If the pwas have a dark brown to black visual appearance then they have 
been either mishandled, were left damp going into their ESD bags or the 
plating is bad. So rules of the road:

1) If the pwas have a yellow to goldish tan visual appearance in an area 
that is not going to be soldered, no action required.

2) If the pwas have a yellow to goldish tan visual appearance in an area 
that is going to be soldered, no action required unless we encounter 
soldering issues. 

3) If the pwas have a light brown visual appearance in any areas of the 
pwa, then we should review our handling procedures to make sure we are not 
putting pwas in bags damp or not handling the pwas by the edges. We should 
also inspect the bare pwbs in stock to see if they have a light brown 
appearance prior to assembly.

4) If the pwas have a dark brown to black visual appearance in any areas 
of the pwa, then we have a problem and need to find root cause.

As you detailed, rubber bands and tape cause major issues for immersion 
silver pwbs turning black due to sulfur and chloride contamination

Dave Hillman
Rockwell Collins 
[log in to unmask]



"Stadem, Richard D." <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
02/09/2011 08:49 AM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
"Stadem, Richard D." <[log in to unmask]>


To
[log in to unmask]
cc

Subject
Re: [TN] IPC-4553






In terms of losing solderability on the secondary side after a single trip 
through the reflow, I think you have immersion silver finish confused with 
immersion tin. Immersion silver does not usually degrade significantly 
after a single reflow excursion.
But again, it depends (ka-ching).
There are many immersion silver plating products, some not as good as 
others, and there is a huge variation amongst the plating companies that 
apply these products. Like any other plating, it depends on which product 
you use, and which plating company or PWB fabricator you use. Some IAg 
products have a much superior co-inhibitor that prevents tarnishing and 
oxidation.
Minor tarnishing (yellowing) of immersion silver has very little effect on 
the DPMO of a given PWB. Black areas caused by direct contact with 
sulfur-bearing desiccant packages, rubber bands, tape, paper (including 
the Moisture Indicator cards) are a completely different story; these will 
have significant impact on solderability, and the flux has little or no 
effect on this.


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Glidden, Kevin
Sent: Wednesday, February 09, 2011 8:33 AM
To: [log in to unmask]
Subject: Re: [TN] IPC-4553

Good point.  Solderability depends heavily on your flux I would say. Those 
using a high activity, halide containing formulation would have an easier 
time than those with ROL0.  Plus, the additional predicament is that the 
oxidation may be minor when the PCBs are received, and they solder just 
fine, but after 6 months or so in stock it is worse, or even after 1 trip 
down the reflow oven making Side 2 unsolderable.


-----Original Message-----
From: Jack Olson [mailto:[log in to unmask]] 
Sent: Wednesday, February 09, 2011 9:11 AM
To: [log in to unmask]; Glidden, Kevin
Cc: Jack Olson
Subject: Re: IPC-4553

Good question.... and when looking at an actual board, how is one to 
determine 
visually if we are looking at "staining" or "oxidation/corrosion"? 
Inquiring minds 
want to know. 
(many would say that even oxidized boards are solderable and acceptable. 
right? I think I just read that somewhere...)

Jack

.
On Tue, 8 Feb 2011 09:20:44 -0500, Glidden, Kevin 
<[log in to unmask]> wrote:

>Morning everyone,
>I have a question on IPC-4553, specifically, section 3.1 "Visual", and 
specifically regarding staining of immersion silver.  The text states "The 

coverage shall be complete and the finish shall be uniform on the surface 
to be 
plated (see Figures 3-1 through 3-5 for properties visually identified 
with IAg 
plated surfaces)"  Figure 3-1 shows 'Example of Uniform Plating", with no 
staining.  Figures 3-2 through 3-5 show staining.  Is this to imply 
(without text 
to support) that any staining of immersion silver is determined to be non-
uniform and therefore a defect?
>Thanks.
>




______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site 
http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional 
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site 
http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional 
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 
ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2