For the first, we use VPR at a couple of suppliers, Jabil and Venture, but they 
don't have the capability at all sites.

For the second, the concern is that the standard flux used in tin-lead paste 
typically will not survive 240C.  It will burn out and you won't get good joints.  
You can use tin-lead with higher temperature flux.

---------------------------------------------------