Hi Inge,
You give me precious little to go on, BUT...
Partially filled barrels certainly have a stress-concentration at the fill/no-fill level.  HOWEVER, most operating environments are benign enough that this is not an issue.  -55/+125 is NOT an operating environment, but a misguided test environment, and YES for this environment the stress riser presents a definitive risk for the z-axis deferential thermal expansion.
BTW, who is 'The Eagle'?
Werner

 

 


 

 

-----Original Message-----
From: Inge Hernefjord <[log in to unmask]>
To: Werner Engelmaier <[log in to unmask]>
Cc: [log in to unmask]
Sent: Wed, Feb 2, 2011 3:56 pm
Subject: Re: [TN] IPC-TM-650 2.6.8, Thermal Stress, PTHs


By the way, been discussing LTCC vias with the Eagle. Gold system, vias mixed system (Au/Ag). Substrates 2x2", Kovar frame, Molly sink. Some vias not entirely filled, look more like barrels than plugs. Squeege printing issue. Did  not like the vias, but was overrun by QC/QA/PM. So the substrates go for production the next days. The Eagle believes they might work. 
 
Q: LTCC structure very stiff and little dx/X/dy/Y, but what about dz/Z? Assume that the poorly filled vias got a rudimentary contact with the imbedded power trace or GND, do you think there is any dt/T -55/+125 risk?
 
Inge


On 2 February 2011 21:36, Werner Engelmaier <[log in to unmask]> wrote:

Hi Inge,
Those were 'the good old days'—well. very good in terms of resources and freedom, not so good when it came to the organization [I still have an occasional nightmare].
This equation has been somewhat updated since, it is in IPC-D-279 and I teach it in some of my workshops.
You sure have an incredible memory and/or a incredibly organized reference library.
Werner 












-----Original Message-----
From: Inge Hernefjord <[log in to unmask]>
To: TechNet E-Mail Forum <[log in to unmask]>; Werner Engelmaier <[log in to unmask]>
Sent: Wed, Feb 2, 2011 3:21 pm
Subject: Re: [TN] IPC-TM-650 2.6.8, Thermal Stress, PTHs


 
W, I have a old report, Predicting Plated-Through-Hole Reliability in a High Temperature Manufacturing Environment, in which one equattion is ' Engelmaier eq.'
The report is written by DEC . If it could be of any help, I can send a copy, alt. you may find it in IEEE'S ARCHIVE.
 
 
 
Inge


 
On 1 February 2011 20:44, Werner Engelmaier <[log in to unmask]> wrote:

 Hi Victor "X" (?),

 Why would you want to "shock the IP layers"? What would that accomplish?
What you want to do, and this test does, is expose your PCB to elevated temperatures to get an idea as how it is holding up in temperature excursions during soldering operations and subsequent operational T-cycles.
Werner







-----Original Message-----
From: Victor Hernandez <[log in to unmask]>
To: [log in to unmask]
Sent: Tue, Feb 1, 2011 2:20 pm
Subject: [TN] IPC-TM-650   2.6.8,  Thermal Stress,  PTHs





Folks,



  As I understand the above mentioned Test Method is reserve for PTH

product/boards.   What application is used when all of the PTH are filled with

non conductive maters, plated over, planarized and covered with solder mask.   I

don't see how the above test would shock the IP layers.



"X"





______________________________________________________________________

This email has been scanned by the MessageLabs Email Security System.

For more information please contact helpdesk at x2960 or [log in to unmask]

______________________________________________________________________



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums

for additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------




______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------








 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2