The ceramic cap termination is touching one of the solder joint ball
(reducing it's volume) and very close to the adjacent via hole (may cause
short).
I think it should be repaired.
Reuven
On Fri, Feb 11, 2011 at 7:37 PM, Genny Gibbard <[log in to unmask]>wrote:
> Please see the link below.
> Cap under BGA.
> Inquiring minds question: If the board tested out OK, would you ever
> consider just leaving this here? The part is a ceramic cap.
>
>
> ________________________________
>
> From: Steve Gregory [mailto:[log in to unmask]]
> Sent: February 11, 2011 10:37 AM
> To: Genny
> Subject: RE: What would you do?
>
>
>
> Hi Genny,
>
>
>
> I have your picture posted:
>
>
>
> http://stevezeva.homestead.com/part_under_BGA.jpg
>
>
>
> It depends. First thing I would want to know, what is this? Is it metal?
> If it is, it would be a violation of electrical spacing and I wouldn't
> leave it there.
>
>
>
> Does the ball have any function? Some balls have no function.
>
> What is this board for? A critical application? If it is then no.
>
> How scarce is the BGA?
>
>
>
> There's a lot of "it depends" that would have to be answered before I
> would consider it.
>
>
>
> My first reaction is that I wouldn't leave it there. But there may be
> some circumstances that I might consider it.
>
>
>
> Steve
>
>
>
> From: Genny
>
> Sent: Friday, February 11, 2011 10:32 AM
> To: Steve Gregory
> Subject: What would you do?
>
>
>
> <<part under BGA.jpg>>
>
> Genny
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
>
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|