Genny,

Based on your X-ray image I have two observations to make.

1. The part appears to be a resistor not a capacitor.  It looks very much like it 
has three sided terminations not 5 sided terminations.

2. One end of the part is reflowed to the solder ball and the other end
(termination) is laying over a via.

You have a potential connection at the via, if it is not connected now.  I 
would say reject or rework unless a failure represents no issue with the end 
user or the customer.  Generally any failure upsets the users and the customer.

Remember this is just my opinion.  My opinions are not infallible

Drew Meyer

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2