The cap might test OK if the via or BGA ball is actually not used or the test is DC.
In a switching circuit the cap is going to effect the signal that it ias coupled to.
The cap violates electrical spacing and if with vibration it breaks free and moves then you have to remove the BGA and fix it anyway but at much higher cost.
----- Original Message -----
From: "Genny Gibbard" <[log in to unmask]>
To: [log in to unmask]
Sent: Friday, February 11, 2011 12:37:01 PM
Subject: [TN] FW: What would you do?
Please see the link below.
Cap under BGA.
Inquiring minds question: If the board tested out OK, would you ever
consider just leaving this here? The part is a ceramic cap.
________________________________
From: Steve Gregory [mailto:[log in to unmask]]
Sent: February 11, 2011 10:37 AM
To: Genny
Subject: RE: What would you do?
Hi Genny,
I have your picture posted:
http://stevezeva.homestead.com/part_under_BGA.jpg
It depends. First thing I would want to know, what is this? Is it metal?
If it is, it would be a violation of electrical spacing and I wouldn't
leave it there.
Does the ball have any function? Some balls have no function.
What is this board for? A critical application? If it is then no.
How scarce is the BGA?
There's a lot of "it depends" that would have to be answered before I
would consider it.
My first reaction is that I wouldn't leave it there. But there may be
some circumstances that I might consider it.
Steve
From: Genny
Sent: Friday, February 11, 2011 10:32 AM
To: Steve Gregory
Subject: What would you do?
<<part under BGA.jpg>>
Genny
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|