>Think of it as a parking lot and your Manufacturing Engineer is trying
>to keep all the cars parked parallel.
But will his car start without being pushed? 20 years ago and
counting Phil... :-)
>Hope this helps....
>
>Phil
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Cote, Clint (GE
>Intelligent Platforms, US)
>Sent: Tuesday, January 11, 2011 9:58 AM
>To: [log in to unmask]
>Subject: [TN] Trace Widths Entering SMT
>
>Our Manufacturing Engineer requires us to have a maximum 0.020" trace
>entering an SMT pad. This is regardless of the size of the pad. He will
>allow multiple 0.020" traces to the same pad. For instance he will allow
>3 0.020" traces into a pad but reject one 0.050" trace. Does this make
>any sense?
>
>Thanks,
>Clint Cote
>
>______________________________________________________________________
>This email has been scanned by the MessageLabs Email Security System.
>For more information please contact helpdesk at x2960 or
>[log in to unmask]
>______________________________________________________________________
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text
>in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at:
>http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
>ext.2815
>-----------------------------------------------------
>
>------------------------------------------------------------------------------
>This message and any attachments are solely for the use of the
>addressee and may contain L-3 proprietary information that may also
>be defined as USG export controlled technical data. If you are not
>the intended recipient, any disclosure, use or distribution of its
>content is prohibited. Please notify the sender by reply e-mail and
>immediately delete this message and any attachments.
>
>
>
>
>______________________________________________________________________
>This email has been scanned by the MessageLabs Email Security System.
>For more information please contact helpdesk at x2960 or [log in to unmask]
>______________________________________________________________________
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for
>additional information, or contact Keach Sasamori at [log in to unmask]
>or 847-615-7100 ext.2815
>-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|