Remember, the old water could conduct charge back to earth ground.  Now, your DI water, through the plastic tubing cannot carry charge.  Maybe not much change except the water cannot bleed off the  static charge. 





-----Original Message-----
From: Phil Bavaro <[log in to unmask]>
To: TechNet <[log in to unmask]>
Sent: Wed, Jan 5, 2011 3:24 pm
Subject: Re: [TN] Deionized water in misting fans and static electricity


Steve,
I thought you had meant that your misting spray was charged but you are
nly talking about the equipment seems to be "poking" you.
I would check the grounding of the fan and make sure the fan cage is
ied into the earth ground.  
I hope you are using a GFCI to plug the fans into.
Phil

-----Original Message-----
rom: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
ent: Wednesday, January 05, 2011 11:53 AM
o: [log in to unmask]
ubject: Re: [TN] Deionized water in misting fans and static electricity
It didn't last year when we ran the fans on tap water. I was up all
round
hem and didn't a static shock I did this year...
We have a high pressure pump that pressurizes the water to around
00-1000
si and pumps the water through about 75-ft of high-pressure plastic
ubing,
nd then goes to misting rings that are zip-tied to the fan blade cover
f
he floor fans to disperse the water:
http://stevezeva.homestead.com/Misting_Fans.JPG
This is the second year that we've been using it. It keeps the humidity
evel between 35%-40% on the shop floor. We need it during the winter.
Last year when used it, we had a lot of "dusting" because we were using
ap
ater. This year we put a DI column on the water source.
How I come across the static charge is because I noticed that some water
ad
egun collecting at the base of fans. I went up to check why (the fans
re
n top of our offices inside our manufacturing space). When I approached
nd
ouched the metal cage around the fan, I got a little "poke" from the
tatic. 
The water is puddling (I think) because it's being attracted to the
etal
an blades and slinging off the blades to collect on the fan cage and
hen
rip to the ground. The fans weren't doing this last year when we ran
hem
n tap water...
Steve
-----Original Message-----
rom: Robert Kondner [mailto:[log in to unmask]] 
ent: Wednesday, January 05, 2011 2:10 PM
o: 'TechNet E-Mail Forum'; 'Steve Gregory'
ubject: RE: [TN] Deionized water in misting fans and static electricity
Steve<
 DI is a heck of an insulator. I assume tap water did not do this?
Bob K.
-----Original Message-----
rom: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
ent: Wednesday, January 05, 2011 1:32 PM
o: [log in to unmask]
ubject: [TN] Deionized water in misting fans and static electricity
This may be an off the wall question but here goes.
 
We have some misting fans that we use for humidification that we've just
ecently put in a deionized water source for. 
 
Now it seems that there's a static charge being generated at the fans
hat
've never noticed before. Could it be possible that we're generating a
harge at the fans because of the DI water?
 
Steve

______________________________________________________________________
his email has been scanned by the MessageLabs Email Security System.
or more information please contact helpdesk at x2960 or
[log in to unmask]
_____________________________________________________________________
---------------------------------------------------
echnet Mail List provided as a service by IPC using LISTSERV 15.0 To
nsubscribe, send a message to [log in to unmask] with following text in
he
ODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
re-start) delivery of Technet send e-mail to [log in to unmask]: SET
echnet
OMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
-mail to [log in to unmask]: SET Technet Digest Search the archives of
revious posts at: http://listserv.ipc.org/archives Please visit IPC web
ite http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for
dditional
nformation, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
xt.2815
----------------------------------------------------

_____________________________________________________________________
his email has been scanned by the MessageLabs Email Security System.
or more information please contact helpdesk at x2960 or
[log in to unmask] 
_____________________________________________________________________
---------------------------------------------------
echnet Mail List provided as a service by IPC using LISTSERV 15.0
o unsubscribe, send a message to [log in to unmask] with following text
n
he BODY (NOT the subject field): SIGNOFF Technet
o temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
o receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
earch the archives of previous posts at:
ttp://listserv.ipc.org/archives
lease visit IPC web site
ttp://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional
nformation, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
xt.2815
----------------------------------------------------
------------------------------------------------------------------------------
his message and any attachments are solely for the use of the addressee and may 
ontain L-3 proprietary information that may also be defined as USG export 
ontrolled technical data. If you are not the intended recipient, any 
isclosure, use or distribution of its content is prohibited. Please notify the 
ender by reply e-mail and immediately delete this message and any attachments.


_____________________________________________________________________
his email has been scanned by the MessageLabs Email Security System.
or more information please contact helpdesk at x2960 or [log in to unmask] 
_____________________________________________________________________
---------------------------------------------------
echnet Mail List provided as a service by IPC using LISTSERV 15.0
o unsubscribe, send a message to [log in to unmask] with following text in
he BODY (NOT the subject field): SIGNOFF Technet
o temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
o receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
earch the archives of previous posts at: http://listserv.ipc.org/archives
lease visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums 
or additional information, or contact Keach Sasamori at [log in to unmask] or 
47-615-7100 ext.2815
----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2