In the 610 -rev E, clause 7.1.2.2 on page 7-9 deals with lead forming and stress relief. The first criteria mentions lead bends less than 1 lead diameter away from the body being only a process indicator for Class 2. The criteria directly below that calls No stress relief a Defect for Class 2.
It seems a little contradictory to me. If you place a bend less than 1 lead diameter away from the seal, is that really any different than no bend whatsoever? It seems to be splitting hairs and from a practical standpoint, a little difficult to tell the difference.
Any thoughts?
Best Regards,
Jeff
Jeff Popp
Quality Assurance Technician
Compunetix, Inc.
2420 Mosside Blvd.
Monroeville, PA 15146
(412) 858-6184
[log in to unmask]<mailto:[log in to unmask]>
[J-STD-001 Instructor logo 2c]
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/ContentPage.aspx?Pageid=E-mail-Forums for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|