Subject: | |
From: | |
Reply To: | |
Date: | Wed, 1 Dec 2010 13:43:06 +0000 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
A single BOM is released for Rev control.
The assembly and inspection visual aides for pre-wave, post wave and mechanical assembly have the part numbers for the parts to be installed on the applicable page: work cell or station (progressive assembly line), therefore no BOM is required but we provide one in each area doc package:.
- Master DOC file, SMT doc package, Pre-wave/Post Wave Hand assembly, Mechanical assembly and Final Inspection.
John Goulet
MFG/Process Engineer
----- Original Message -----
From: "Rick Smith" <[log in to unmask]>
To: [log in to unmask]
Sent: Tuesday, November 30, 2010 10:30:26 AM
Subject: [TN] Separate BOM's for Same Assembly
Hi Folks,
Engineering currently produces two separate BOM's for a single board assembly, 1 for SMD's and the other for PTH parts which are subsequently entered into the ERP system by Doc Control. Without going into a lot of detail I understand the reasons for the separate BOM's are related to production logistics, routings and cost.
I am told this is typical in the industry for OEM's and would like to either corroborate or debunk this with your responses. I am trying to determine if the 2 BOM system is necessitated by ERP limitations or the result of a misguided approach to process development.
Does anyone use the two BOM approach for a single board assembly?
Thanks!
Regards,
Rick
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|