We use 1 BOM for the entire assembly, but the BOM is broken down into
work centers so the SMT parts are assigned to one work center, the THT
parts are assigned to a second work center, and mechanical/housing parts
to a third work center.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Smith, Rick
Sent: Tuesday, November 30, 2010 9:30 AM
To: [log in to unmask]
Subject: [TN] Separate BOM's for Same Assembly

Hi Folks,

Engineering currently produces two separate BOM's for a single board
assembly, 1 for SMD's and the other for PTH parts which are subsequently
entered into the ERP system by Doc Control. Without going into a lot of
detail I understand the reasons for the separate BOM's are related to
production logistics, routings and cost.

I am told this is typical in the industry for OEM's and would like to
either corroborate or debunk this with your responses. I am trying to
determine if the 2 BOM system is necessitated by ERP limitations or the
result of a misguided approach to process development.

Does anyone use the two BOM approach for a single board assembly?

Thanks!

Regards,
Rick


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2