Ann,
You may not love my opinion. Personally, I think that the beta or whatever 
thickness testing is not telling much about the wetting and final solder 
joint quality. Instead one should rely upon a solder wetting (balance) 
testing combined with solder ball shear tests. Depending on what customer 
you have, there may be necessary with even more tests, e.g. tempcycling and 
ageing tests with X-sectioning and SEM/EDX. But there are simpler ways to 
start with . A experienced quality/process engineer can use a hard 
typewriter eraser and get a good opinion just by making a few strikes (not 
recommended for everyone to do!).  Furthermore, you can use IPC-4552, which 
involves tape testing. Again, I don't say Fisherscope is improper, but it is 
not a fair judge.
Myself, I gave our istrument to people who plated car details, motorway stel 
barriers and such things. THERE, it's very worthful.

Please, don't throw bottles on me. At least not if they are empty.

Inge

PS. If you are lucky to have a very good SEM driver, he/she can estimate the 
flash gold by doing a programmed stepwise scan with Backscatter detector 
(the acc voltage is important). Calibrate the grayscale level by means of 
sputtered gold on a nickel plate.



----- Original Message ----- 
From: "IMI TAN, Ann Jovelyn B." <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, October 28, 2010 1:00 PM
Subject: [TN] FW: Inquiry on ENIG thickness Measurements


Hi Technet Members,



We have been encountering several miscorrelation callouts with our
suppliers with regards to the measurement of the ENIG coating of the
PCBs we order from them. This is considering different equipment sets
used (suppliers normally use the Oxford CMI 900 while we use the
Fischerscope XDAL), and collimator sizes. All other settings are taken
from IPC 4552. I would like to clarify a few points:

1.       When taking the actual thickness to be reported, should we take
readings from multiple pads and take the average? Should the average be
the reported value? In case one pad fails but the average passes, should
the board be judged as acceptable?

2.       Does the IPC 6012 rev C supersede even the Amendment in IPC
6012 B which states that the requirement for gold thickness only applies
to non-solderable surfaces? Does this mean that the 0.05um minimum
thickness specified in the IPC 6012 C would apply to all pads?









Thank you,

Ann Jovelyn B. Tan

Supplier Quality Engineer

Corporate Quality and Reliability

Integrated Microelectronics, Incorporated

#103 Trade Avenue cor Technology Avenue

Special Export Processing Zone

Laguna Technopark, Phase 4 Binan, Laguna 4024

Philippines

Tel:  +63 49 541 2440 to 55 local 3569/3550

Mobile: +63 923 288 1127

Email: [log in to unmask]
<mailto:[log in to unmask]>

http://www.global-imi.com <http://www.global-imi.com/>



A member of the IMI group of companies



IMI is a global vertically-integrated electronics manufacturing services
(EMS) provider well-known for its flexible expertise.




This is a virus free email...

This e-mail message and all contents are intended only for the named 
recipients(s). The information contained herein may be confidential or 
privileged, and its disclosure, distribution or reproduction is prohibited.

If you are not the named recipient, please return it immediately to its 
sender at the above address and destroy the original message and all copies.


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
----------------------------------------------------- 


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2