Ken,

Assuming you are using IPA to clean your rosin residues and thus occasionally getting the white residues, for your applications I would recommend looking at your soldering temperature first.  If it is too high it could be helping to create your white residues.

The most common cause of white residue is oxidation of rosin. Rosin flux constituents oxidize due to excessive solder temperature, flux aging, or moisture when the rosin-fluxed assemblies are cleaned with organic solvents. Polymerization of small amounts of rosin from heat exposure may also play a role in the formation of white residue.

If your soldering temperature is not excessive then look into a separate cleaning chemistry for your current soldering process.  I have had good success with Terpene based cleaners for rosin.

Regards,
Tom Carroll, CQA, CIT, FAA ODA Unit Member
Supplier Quality Engineer
Boeing Defense, Space and Security - East Region Supplier Quality
Currently on Short Term International Assignment for BCA in Sweden
eFAX: 314-777-1845
Cell: 215-692-2463
Softphone Phone Number: 314-545-2358
Saab Sweden Phone: +46 (0)13 185972
Sweden Cell Phone (In Sweden): 0700 945414
Sweden Cell Phone (Outside of Sweden): +46 700 945414
email: [log in to unmask]

P Go Green! Please do not print this e-mail unless necessary.

>NOTE: This communication may contain privileged or other confidential information. If you are not the intended recipient, or believe you have received this communication in error, please do not print, copy, retransmit, disseminate, or otherwise use the information. Also, please indicate to the sender that you have received this e-mail in error, and delete the copy you received. Thank you.
>EXPORT COMPLIANCE STATEMENT:
>"The information contained herein is or may be controlled by the International Traffic in Arms Regulations (ITAR), 22 CFR 120-130, and may not be exported, or disclosed to a foreign person, whether in the United States or abroad, without prior U.S. Government written approval"

-----Original Message-----
From: Kenneth Wood [mailto:[log in to unmask]] 
Sent: Monday, September 06, 2010 3:11 PM
To: 'TechNet E-Mail Forum'; Carroll, Thomas A
Subject: RE: [TN] Hand Soldering

Well, the PCB's can be any thickness really and I use multiple surface finishes but primarily HASL and ENIG.
I'm using standard Kester rosin core solder.
The main use is building prototypes on my bench so it doesn't have to meet any certain classes or requirements...just would like it to clean up better.
Ken

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Carroll, Thomas A
Sent: Monday, September 06, 2010 8:51 AM
To: [log in to unmask]
Subject: Re: [TN] Hand Soldering

Ken,

Tough question without more details.  The best setup depends upon a number of factors including but not limited to the following:

PWB surface finish
PWB thickness (heat sink properties)
Component surface finish
Are you using additional liquid flux or just flux cored solder wire 
Solder alloy being added 
Ease of cleaning soldered area 
Type of cleaning used (cleaning media and hand or machine process) 
Post Soldering Ionic Cleanliness requirements 
Post Soldering Non-Ionic Cleanliness requirements

I can go on but you get the idea.

Provide more details and you should get the response you desire.

Regards,
Tom Carroll, CQA, CIT, FAA ODA Unit Member Supplier Quality Engineer Boeing Defense, Space and Security - East Region Supplier Quality Currently on Short Term International Assignment for BCA in Sweden
eFAX: 314-777-1845
Cell: 215-692-2463
Softphone Phone Number: 314-545-2358
Saab Sweden Phone: +46 (0)13 185972
Sweden Cell Phone (In Sweden): 0700 945414 Sweden Cell Phone (Outside of Sweden): +46 700 945414
email: [log in to unmask]

P Go Green! Please do not print this e-mail unless necessary.

>NOTE: This communication may contain privileged or other confidential
information. If you are not the intended recipient, or believe you have received this communication in error, please do not print, copy, retransmit, disseminate, or otherwise use the information. Also, please indicate to the sender that you have received this e-mail in error, and delete the copy you received. Thank you.
>EXPORT COMPLIANCE STATEMENT:
>"The information contained herein is or may be controlled by the
International Traffic in Arms Regulations (ITAR), 22 CFR 120-130, and may not be exported, or disclosed to a foreign person, whether in the United States or abroad, without prior U.S. Government written approval"

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kenneth Wood
Sent: Monday, September 06, 2010 2:30 PM
To: [log in to unmask]
Subject: [TN] Hand Soldering

Hi all.
What is the best setup for hand soldering as far as solder / cleaner?
Rosin core? Water soluble? No-Clean?
What cleaner too?

I've been using rosin core with various cleaners but I have a hard time with the white residue the cleaners leave.

Thanks
Ken





______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2