TECHNET Archives

September 2010

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
vladimir Igoshev <[log in to unmask]>
Reply To:
Date:
Fri, 17 Sep 2010 16:38:57 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (1 lines)
Chris,

If you know a company willing to pay the cost of FIB for that kind of task, please let me know. I wouldn't mind get them as a customer :-)
Vladimir

SENTEC Testing Laboratory Inc.
11 Canadian Road, Unit 7.
Scarborough, ON M1R 5G1
Tel: (416) 899-1882
Fax: (905) 882-8812
www.sentec.ca

-----Original Message-----
From: Chris Mahanna <[log in to unmask]>
Sender: TechNet <[log in to unmask]>
Date:         Fri, 17 Sep 2010 12:31:34 
To: <[log in to unmask]>
Reply-To: TechNet E-Mail Forum <[log in to unmask]>,
        Chris Mahanna <[log in to unmask]>
Subject: Re: [TN] How to measure thickness of ENIG plating inside the via barrel

If you want to know the truth, FIB mill it and SEM, with or without microsection.  If you're going to microsection, you better use some excellent mounting material (slow cure epoxy).
Otherwise find some way to XRF, take the numbers and don't ask questions.
It is no mistake that the vast majority of 6012 immersion finish conformance is based strictly on "coverage and solderable".

As for structural integrity from Ni, definitely true.  Thickness is easily measured in microsection.

Chris

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2