IPC-620 has the following statement in section 1.8.

"When IPC/WHMA-A-620 is cited or required by contract as a stand-alone document for inspection and/or acceptance, the requirements of J-STD-001 Requirements for Soldered Electronic and Electronic Assemblies or IPC-A-610 Acceptability of Electronic Assemblies do not apply unless separately and specifically required."

I think that's pretty clear, none of the requirements of J-STD-001, including training are required.

Gregg

-----Original Message-----
From: Tan Geok Ang [mailto:[log in to unmask]] 
Sent: Friday, September 17, 2010 1:35 AM
To: [log in to unmask]
Subject: [TN] IPC-WHA-620 and J-001

Hi All, I will like to check with you all,
a) If one is trained in IPC-620, must he/she be trained on J-001 so that he is allowed to perform the soldering process during cable assembly? 
b) J-001 touches on rework and repair, thus will one be able to perform repair/rework base on J-001 or strictly speaking he/she must be trained on IPC 7711/7721?
 
Thanks!

 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2