 Hi Chris,
How hot is hot?

 With a thick=stiff spreader, co-planarity will be forced by the solder creeping rather fast at the higher T's.
Werner


 

 

-----Original Message-----
From: Chris Mahanna <[log in to unmask]>
To: Werner Engelmaier <[log in to unmask]>; [log in to unmask] <[log in to unmask]>
Sent: Tue, Sep 14, 2010 9:34 am
Subject: RE: [TN] Bergquist Gap Pad



Werner,
Yes, definitely agreed.  
We and our customer had been ignoring this part of the study for that reason. But, we have picked up on some planarity issues between the heat spreader (it’srather thick) and the board.  Also the clips are rather low force.
So, brainstorming.. I thought there might be a differentialcompression across the BGA, combined with all the differential CTEs…  Thesethings got hot.
Just a thought.
Wondering if anyone had been there and got the t-shirt already.
 
Chris
 

From: Werner Engelmaier[mailto:[log in to unmask]] 
Sent: Tuesday, September 14, 2010 9:17 AM
To: [log in to unmask]; Chris Mahanna
Subject: Re: [TN] Bergquist Gap Pad

 

Hi Chris,
These clips would put the SJs into compression—that means that even whenfatigued to fracture, you will not see a functional failure.
Werner

 

 

 

-----Original Message-----
From: Chris Mahanna <[log in to unmask]>
To: [log in to unmask]
Sent: Mon, Sep 13, 2010 10:25 pm
Subject: [TN] Bergquist Gap Pad

We are working on a memory module FA.  Sandwich looks like this:








 
top of clip








 
Ni plated Cu heat spreader (goes across all 8 BGAs)








 
Gap Pad








 
8 BGAs in a single row








 
board








 
Gap Pad








 
bottom of clip








 









 
Has anyone seen more than [expected] damage after natural field cycling (maybe) 








 
caused by the gap pad?  The material appears to be patented for low-modulus, 








 
high W/mk  but...








 









 
Chris








 









 









 
______________________________________________________________________








 
This email has been scanned by the MessageLabs Email Security System.








 
For more information please contact helpdesk at x2960 or [log in to unmask] 








 
______________________________________________________________________








 









 
---------------------------------------------------








 
Technet Mail List provided as a service by IPC using LISTSERV 15.0








 
To unsubscribe, send a message to [log in to unmask] with following text in








 
the BODY (NOT the subject field): SIGNOFF Technet








 
To temporarily halt or (re-start) delivery of Technet send e-mail to 








 
[log in to unmask]: SET Technet NOMAIL or (MAIL)








 
To receive ONE mailing per day of all the posts: send e-mail to 








 
[log in to unmask]: SET Technet Digest








 
Search the archives of previous posts at: http://listserv.ipc.org/archives








 
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 








 
additional information, or contact Keach Sasamori at [log in to unmask] or 








 
847-615-7100 ext.2815








 
-----------------------------------------------------








 


 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2