Doug,
You have arcing going on. We have seen this before. Charges build up and
you get a lightening bolt from the electrode to the board.
I suggest you turn down the power by half and extend your cycle time.
good luck,
Chuck Brummer l 3M Manufacturing Engineer
3m Electronic Solutions Division--Flexible Circuits
8357 Canoga Ave. l Canoga Park, CA 91304-2605
(818) 734-4930
[log in to unmask] l www.3m.com l www.3mFlex.com
From:
Douglas Pauls <[log in to unmask]>
To:
[log in to unmask]
Date:
08/16/2010 06:07 AM
Subject:
[TN] plasma question
Sent by:
TechNet <[log in to unmask]>
Good morning all,
For those of you who have used plasma etching on circuit assemblies, I
have a question. One of our operators observed "sparking" through the
plasma chamber viewport and a transistor was fried. Any idea what causes
this? First time we have seen this.
Doug Pauls
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|