i beleive its non-conforming.
Joey Rios
PWB & Process Quality Eng'r
Endicott Interconnect Technologies
1093 Clark St.
Endicott, NY 13760
Office: 607-755-5896
Chris Mahanna <[log in to unmask]>
Sent by: IPC-600-6012 <[log in to unmask]>
08/16/2010 01:20 PM
Please respond to
"(Combined Forum of D-33a and 7-31a Subcommittees)" <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[IPC-600-6012] opinion poll
Hi Everyone,
Attached is a picture of a thru-hole corner after thermal stress. The
plating is pulse. I believe the corner was 'burnt' because of the
geometry of the (conformant) negative etchback. All the corners show
burn; some show blisters; only this one cracked.
In your opinion, what are the non-conformance(s) if any?
Thanks
Chris
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________[attachment
"corner.jpg" deleted by Jose A Rios/Endicott/EIT]
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________