 Hi Michael,
Nowhere did I say that IS 410 is equal to PC370HR; all I said that both of these Pb-free capable materials are now materials sold by Isola, since Isola gobbled up Polyclad.

 However, int terms of the properties important for Pb-free capability they are not that far apart.
IS 410        [Tg=170C, Td=350C, TE=3.5%, STII=225 ]

 PC 370HR [Tg=170C, Td=340C, TE=2.8%, STII=227 ]
Werner

 

-----Original Message-----
From: Jeremias, Michael <[log in to unmask]>
To: [log in to unmask]
Sent: Tue, Jul 6, 2010 6:14 am
Subject: [TN] AW: [TN] MIL-S-13949/EPS0606/IPC-1710 etc


 





Hello Partners, hi Werner



Pay  attention!



IS 410 is not equal PC 370 HR.



IS 410 is not filled while  PC 370 HR is a filled material with quite

different properties mainly in withstanding lead free soldering

temperatures, if You use it with thick multilayers and through hole

vias.



 Sincerly 



Michael Jeremias   

Industrial Engineering (OPPI41) 

Electronics Production 

((( Defence Electronics 

EADS Deutschland GmbH 

89077 Ulm

 

 



From: Werner Engelmaier [mailto:[log in to unmask]]

Sent: Friday, July 02, 2010 10:07 AM

To: [log in to unmask]; [log in to unmask]

Subject: Re: [TN] MIL-S-13949/EPS0606/IPC-1710 etc



 



Hi Ken,

You sure have quite a mish-mush.

There is no such thing as IPC-SM-750.

IS410 is an Isola lead-free capable base material as is 370 HR

[originally from Polyclad]



Tg and Td are material properties important for being lead-free capable/

IPC 4101 is an IPC document in its C revision, /129, /24 and /26 are

base material categories.



IPC-A-600 is an assembly spec.

If your drawing has nothing but it on it, your PCB is inadequately

specified.

In order to understand all of this and how it hangs together, you may

want to get my White Paper [see my website].



 



Regards,



Werner Engelmaier



Engelmaier Associates, L.C.



Electronic Packaging, Interconnection and Reliability Consulting



7 Jasmine Run



Ormond Beach, FL 32174 USA



Phone: 386-437-8747, Cell: 386-316-5904



E-mail: [log in to unmask], Website: www.engelmaier.com



 



 



-----Original Message-----

From: Ken Barton <[log in to unmask]>

To: [log in to unmask]

Sent: Fri, Jul 2, 2010 12:31 pm

Subject: [TN] MIL-S-13949/EPS0606/IPC-1710 etc



Good day helpful gurus,













 

I am the lone PCB layout person working at a new company with













 

outdated/obsolete (MIL0S-13949 for example) fab drawing notes. Our PCB

fab













 

vendor's cert of compliance states that out boards are built per:













 

SM-750/IS410/370HR Tg180 C Td 350 (IPC 4101/129, IPC 4101/24.26, IPC

4552













 

for immersion gold.













 















 

 













 















 

The only IPC reference/spec on our drawings is A-600.













 















 

 













 















 

Please recommend which IPC standards to purchase that refer to/specify













 

standards for class III aerospace type PCBs, and if anyone can fill me

in on













 

EPS0606, I'm not getting very far with the web search.













 















 

 













 















 

Thanks, 













 















 

 













 















 

Ken Barton













 















 

Luma Technologies













 















 

(425) 643-4000 x304













 















 

[log in to unmask]













 















 

Visit us at www.lumatech.com













 















 

 













 















 















 















 

______________________________________________________________________













 

This email has been scanned by the MessageLabs Email Security System.













 

For more information please contact helpdesk at x2960 or

[log in to unmask] 













 

______________________________________________________________________













 















 

---------------------------------------------------













 

Technet Mail List provided as a service by IPC using LISTSERV 15.0













 

To unsubscribe, send a message to [log in to unmask] with following text

in













 

the BODY (NOT the subject field): SIGNOFF Technet













 

To temporarily halt or (re-start) delivery of Technet send e-mail to 













 

[log in to unmask]: SET Technet NOMAIL or (MAIL)













 

To receive ONE mailing per day of all the posts: send e-mail to 













 

[log in to unmask]: SET Technet Digest













 

Search the archives of previous posts at:

http://listserv.ipc.org/archives













 

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16

for 













 

additional information, or contact Keach Sasamori at [log in to unmask] or 













 

847-615-7100 ext.2815













 

-----------------------------------------------------













 





______________________________________________________________________

This email has been scanned by the MessageLabs Email Security System.

For more information please contact helpdesk at x2960 or

[log in to unmask]

______________________________________________________________________



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to [log in to unmask]: SET

Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the

posts: send e-mail to [log in to unmask]: SET Technet Digest Search the

archives of previous posts at: http://listserv.ipc.org/archives Please

visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



______________________________________________________________________

This email has been scanned by the MessageLabs Email Security System.

For more information please contact helpdesk at x2960 or [log in to unmask] 

______________________________________________________________________



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to 

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 

additional information, or contact Keach Sasamori at [log in to unmask] or 

847-615-7100 ext.2815

-----------------------------------------------------


 

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2