I hope someone on this fourm can help me.  This is the application:
1.0x0.06" ceramic disk with a strip of metalization 800x170 mil. on each
side.
The metalization/trace is sputtered on the ceramic of:
    0.2 microns of Titanium against the ceramic
    1.0 microns of Nickel-Vinadium
    0.8 microns of Silver
    0.4 microns of Titanium
    1.0 microns of Nickel-Vinadium
    1.6 microns of Silver on top (Total of 5 microns of metalization)
 
    A 0.060" high temp solder ball (93.5 Pb, 5 Sn, 1.5 Ag) is built on
the trace near one of
the ends on both sides.  The entire part is then coated with 1-3 mils of
Teflon PFA.  The part
is cured @ 350F for 10 min., then at 650F for another 10 min.  The
solder ball (also coated)
is then cut in half with a wire cutter to make a solderable surface to
make a wire connection.  
    What I am wondering is, is there some type of mask that can be put
down on the trace
instead of a "blob" of solder.  Then removed, and still be able to
solder a wire to the underlying
silver metalization?  The only reason the solder ball is placed on the
part is to be able to have
something to solder to after the coating of the Teflon.  Any other ideas
are welcome.  Thank
you in advance.
 
Best Regards,
 
Michael Forrester
Sr. Product Engineer
 
Siemens Healthcare Diagnostics
101 Silvermine Rd.
Brookfield, CT  06804
PH: (203) 740-6452
 

-------------------------------------------------------------------------------
This message and any included attachments are from Siemens Healthcare Diagnostics
and are intended only for the addressee(s). 
The information contained herein may include trade secrets or privileged or 
otherwise confidential information. Unauthorized review, forwarding, printing, 
copying, distributing, or using such information is strictly prohibited and may 
be unlawful. If you received this message in error, or have reason to believe 
you are not authorized to receive it, please promptly delete this message and 
notify the sender by e-mail with a copy to [log in to unmask]

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2