TECHNET Archives

July 2010

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Fri, 16 Jul 2010 16:15:14 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (81 lines)
Thanks for all your entries.
My problem is not solved but I have a better idea.
But now it's holidays time for me and I'll keep on on august !

Best regards and good holidays,

CANTAGALLO Luigi
[log in to unmask]




Frank Kriesch <[log in to unmask]> 
Envoyé par : TechNet <[log in to unmask]>
16/07/2010 09:49
Veuillez répondre à
TechNet E-Mail Forum <[log in to unmask]>; Veuillez répondre à
[log in to unmask]


A
[log in to unmask]
cc

Objet
Re: [TN] PCB storage






Luigi,

GEIA-STD-0003, Long Term Storage of Electronic Devices

can give you some answers.

Regards

Frank



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of 
[log in to unmask]
Sent: Thursday, July 15, 2010 5:28 AM
To: [log in to unmask]
Subject: [TN] PCB storage

Hello Technetters,

we have to store High reliability SnPb assemblies for some years. They 
will be stored under N2 cabinets and temperature 22°C±2°C.
Are there any standards about the storage times or technical articles on 
the subject ?
Thanks.

CANTAGALLO Luigi
Technology Engineer
[log in to unmask]




______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2