Have certainly seen that in lead-free solder process (wave and selective)
before. Presume you are seeing from assay of your bath contents. We never
really got to the bottom of rising levels in the wave solder bath, but
coincident rising levels of Fe content gave a clue to the problem with the
selective machine which had some minor stainless steel erosion issues. High tin
content and higher alloy temperature will attack solder pump impellor and
ducting etc if not treated to impede erosion. I have a presentation on this
story if you think it might be helpful and I could send a copy by email offline
Higher than normal levels of Ni can supposedly cause "grittiness" and "grainy
joints" with SnPb alloy, but of course at least one patented lead-free alloy in
wide use deliberately adds 0.05% Ni, so it can't be all bad.
Nigel
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------