Last week I purchased Robert's guide "High Powered Printed Circuit Design".

His website is www.megadawn.com

His guide is well worth the $10 he charges.  Just make a payment to his PayPal account, [log in to unmask], and he'll send you a pdf copy.

His website also mentions his long experience racing Mini's (Austin/Morris - not BMW).  Bonus points for that!

Gregg


-----Original Message-----
From: Lum Wee Mei [mailto:[log in to unmask]] 
Sent: Tuesday, June 08, 2010 5:40 PM
To: [log in to unmask]
Subject: Re: [TN] hEAVY COPPER PCB DESIGN RULES

I do not think IPC has any standards that govern PCB with heavy copper but there is someone whom I came across some years back that might be of help to you. He is Robert Tarzwell who wrote the book on "High Power Printed Circuit Design Notebook." This book described some of the guideline on design that use heavy copper. However, I am afraid that I did not have his current contact.
 
Thanks and Regards,
~ Wee Mei ~

________________________________

From: TechNet on behalf of Thomas E Kemp
Sent: Tue 6/8/2010 11:18 PM
To: [log in to unmask]
Subject: Re: [TN] hEAVY COPPER PCB DESIGN RULES



Hi Cedric. Our basic guidelines for 210um (0.0084") thick copper is
.0.018" minimum for both line widths and spacing. One must also take into
consideration factors such as temperature rise, enclosure environment,
etc. Keep in mind that you are also plating inside your through holes, so
you must compensate here as well. I am not aware of an IPC specification
for heavy copper. We invested a considerable amount to develop our
guidelines.

Tom Kemp
Rockwell Collins Printed Circuits
Sr QE



Cedric ORAIN <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
06/08/2010 05:45 AM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Cedric ORAIN <[log in to unmask]>


To
[log in to unmask]
cc

Subject
[TN] hEAVY COPPER PCB DESIGN RULES






Hello Technetters,

I am looking for design rules regarding a 2 sided PCB having 210um of
finished copper. What are the minimum trace width and the minimum
clearance
betweens traces?

Is ther an IPC doc describing this?

Thanks for your answers in advance!

Sincerly,

Cedric


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2