You did not get many responses, probably because hardly anyone measures the
mesh tension at incoming inspection. The main reason for that is the lack of
space to make the measurement reliably. In most instances you have about 1
inch of mesh around the stencil and the most common tensiometers require
more space. You can not make this measurement on the foil itself, as even
without tension it hardly deforms when you place a tensiometer on it. (The
tensiometer has three in-line legs with the middle one being spring loaded.
The deflection of it with respect to the outer two provides an indicator of
the tension in the mesh.)

Ahne.



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kane, Amol (349)
Sent: Thursday, May 13, 2010 06:07
To: [log in to unmask]
Subject: Re: [TN] stenicl tension per stencil thickness

How can you measure this tension on the finished product?....say, maybe as
part of receiving inspection?

Amol



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Bill Kunkle
Sent: Thursday, May 13, 2010 8:37 AM
To: [log in to unmask]
Subject: Re: [TN] stenicl tension per stencil thickness

Geng Yu,

In general the stencil tension may only be measured in the support mesh
area.

Measurements on the foil will vary from stencil to stencil depending on the
foil thickness and different types of foil, as well as depending on the
tension in the support mesh.

Bill Kunkle 
MET Assocs.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Geng Yu
Sent: Wednesday, May 12, 2010 10:28 PM
To: [log in to unmask]
Subject: [TN] stenicl tension per stencil thickness

Hi Technet team,

I'm SMT process engineer, now I encountered 1 question for stencil tension, 

Can you do me a favor?

my company stencil tension standard is >=35N, but this standard was defined
at 5years ago,

At that time no stencil thickness is 3mils, now we used 3mils stencil, we
measured the stencil tension is lower than 35N, so I want to know if the
stencil tension is related the stencil foil thickness, and what is the
stencil tension standard per stencil thickness,

Thanks!

 

 

 

Best wishes

 

Geng Yu 



 


  
Legal Disclaimer:
The information contained in this message may be privileged and
confidential. It is intended to be read only by the individual or entity to
whom it is addressed or by their designee. If the reader of this message is
not the intended recipient, you are on notice that any distribution of this
message, in any form, is strictly prohibited. If you have received this
message in error, please immediately notify the sender and delete or destroy
any copy of this message

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------



WARNING:  Export Control 
This document may contain technical data within the definition of the 
International Traffic in Arms Regulations (ITAR), and subject to the Export 
Control Laws of the U.S. Government.  Transfer of such data by any means to
a 
foreign person, whether in the United States or abroad, without proper
export 
authorization or other approval from the U.S. Department of State is 
prohibited. 
 
CONFIDENTIALITY NOTICE: 
This e-mail, and any attachments, is for the sole use of the intended 
recipient(s) and may contain information that is confidential and 
protected from disclosure under the law. Any unauthorized review, use, 
disclosure, or distribution is prohibited. If you are not the intended 
recipient, please contact the sender by reply e-mail, and delete/destroy 
all copies of the original message and attachments. 
Thank you.

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2