I know, because I introduced NAFI at my company.  I had moments when I hated 
them, because of fretting.  Everything  is vibrating in a jetfighter at 
Mach2, as you know. We had to ask the NAFI makers to modify everything.  My 
worst mistake ever to buy something before it's evaluated and QPL'd.  See, 
there is that NAFI guy....they whispered (I exaggerate a little).
Well, we are using them still after 20 years, but now pressfit.  Our 
pressfit tool works perfectly.  Place the connector in the jig, release 
secure button, grip the large (1 meter) lever and swoop all 6oo pins into 
board within a few seconds. I never thought it would work, but it does.

Inge

--------------------------------------------------
From: "Glidden, Kevin" <[log in to unmask]>
Sent: den 5 May 2010 22:43
To: <[log in to unmask]>
Subject: Re: [TN] M28859/5-02 Press Fit pins

> The MIL-A-28870 connection system is modular using MIL-C-28859 
> components - individual press-fit contacts with a molded insulator that is 
> secondarily installed.  The entire connection system was developed by 
> Naval Avionics Facility, Indianapolis WAY back, and was thus termed the 
> "NAFI" connector.  The modularity allows for infinite configurations of 
> pin counts or arrays.  It is still widely used on hi-rel military 
> backplanes with high pin counts for severe environments.
>
> -----Original Message-----
> From: Inge [mailto:[log in to unmask]]
> Sent: Wednesday, May 05, 2010 4:25 PM
> To: Glidden, Kevin; [log in to unmask]
> Subject: Re: [TN] M28859/5-02 Press Fit pins
>
> I'm not sure I'm understanding the q 100%. We install pressfit connectors
> with hundreds of pins by means of a machine that operates partly with air
> pressure.
> Inge
>
> --------------------------------------------------
> From: "Glidden, Kevin" <[log in to unmask]>
> Sent: den 5 May 2010 18:26
> To: <[log in to unmask]>
> Subject: Re: [TN] M28859/5-02 Press Fit pins
>
>> It doesn't exist - you have to make your own to fit whatever press you 
>> are
>> using...
>>
>>
>> Kevin Glidden
>> Manufacturing Engineer
>> Astronics Luminescent Systems Inc.
>>
>> -----Original Message-----
>> From: Mike Sewell [mailto:[log in to unmask]]
>> Sent: Wednesday, May 05, 2010 11:51 AM
>> To: [log in to unmask]
>> Subject: [TN] M28859/5-02 Press Fit pins
>>
>> Can someone recommend a source for tooling to install these pins?   I'm
>> not finding much beyond the single pin field repair insertion/extraction
>> tools offered by the manufacturer of the pin.
>>
>>
>>
>> Regards,
>>
>> Mike
>>
>>
>> ______________________________________________________________________
>> This email has been scanned by the MessageLabs Email Security System.
>> For more information please contact helpdesk at x2960 or [log in to unmask]
>> ______________________________________________________________________
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 15.0
>> To unsubscribe, send a message to [log in to unmask] with following text in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt or (re-start) delivery of Technet send e-mail to
>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>> To receive ONE mailing per day of all the posts: send e-mail to
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at: 
>> http://listserv.ipc.org/archives
>> Please visit IPC web site 
>> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>> for additional information, or contact Keach Sasamori at [log in to unmask] 
>> or
>> 847-615-7100 ext.2815
>> -----------------------------------------------------
>>
>> ______________________________________________________________________
>> This email has been scanned by the MessageLabs Email Security System.
>> For more information please contact helpdesk at x2960 or [log in to unmask]
>> ______________________________________________________________________
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 15.0
>> To unsubscribe, send a message to [log in to unmask] with following text in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt or (re-start) delivery of Technet send e-mail to
>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>> To receive ONE mailing per day of all the posts: send e-mail to
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at: 
>> http://listserv.ipc.org/archives
>> Please visit IPC web site 
>> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>> for additional information, or contact Keach Sasamori at [log in to unmask] 
>> or
>> 847-615-7100 ext.2815
>> -----------------------------------------------------
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------  


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2