Torsten

Is this for a body implant? If it is, you need to seek help through the FDA in the USA, they seem to have done the most work.

Graham Naisbitt
Gen3 Systems

On 25 May 2010, at 11:30, Torsten Hagge wrote:

> Hi Technetters,
> 
> looking for an conformal coating for electronics used in medical application. The small electronic should be able to pass 1000 cycles washing and cleaning process with ph=13 plus 20 minutes autoclave 135°C @ 2bar.
> 
> 1st idea is parylene coating, any cheaper or better ideas?
> 
> Regards,
> Torsten
> 
> Dipl.Ing.(FH)Torsten Hagge
> tech. projectmanager
> Kristronics GmbH
> Gewerbegrund 5 - 9
> 24955 Harrislee
> 
> Tel.:    +49 461 7741 624
> Fax:     +49 461 7741 642
> [log in to unmask]
> www.kristronics.de
> 
> Gerichtsstand Flensburg, Handelsregister: HRB 1433 FL
> Geschäftsführer Dipl.-Ing. oec. Thormod Ohm
> Ust-Id-Nr. DE 811182059
> Bankverbindung: Deutsche Bank AG Flensburg, Konto-Nr. 4216610, BLZ 21570011
> IBAN: DE32 2157 0011 0421 6610 00, BIC: DEUT DE HH 215
> 
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask] 
> ______________________________________________________________________
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2