Torsten,
About the only coating family that "might" work, aside from Parylene,
would be an epoxy based. If you use an epoxy base, then it would be a
throw away kind of assembly. No rework.
Graham Collins had suggested the Henkel Macromelt, but I think your 135C
autoclave condition, which I assume is happening each time you wash it,
may have a long term effect. The macromelts are a form of polyamide
(nylons), which might degrade.
Overall, I think Parylene is your best bet, primarily because it is
already well established in the medical field.
Doug Pauls
Torsten Hagge <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
05/25/2010 05:30 AM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Torsten Hagge <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[TN] Coating
Hi Technetters,
looking for an conformal coating for electronics used in medical
application. The small electronic should be able to pass 1000 cycles
washing and cleaning process with ph=13 plus 20 minutes autoclave 135°C @
2bar.
1st idea is parylene coating, any cheaper or better ideas?
Regards,
Torsten
Dipl.Ing.(FH)Torsten Hagge
tech. projectmanager
Kristronics GmbH
Gewerbegrund 5 - 9
24955 Harrislee
Tel.: +49 461 7741 624
Fax: +49 461 7741 642
[log in to unmask]
www.kristronics.de
Gerichtsstand Flensburg, Handelsregister: HRB 1433 FL
Geschäftsführer Dipl.-Ing. oec. Thormod Ohm
Ust-Id-Nr. DE 811182059
Bankverbindung: Deutsche Bank AG Flensburg, Konto-Nr. 4216610, BLZ
21570011
IBAN: DE32 2157 0011 0421 6610 00, BIC: DEUT DE HH 215
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|